DIRECTIONAL POWER HEADS
A-14 46882-311D
Using the directional power head accessory
General
The supplied accessory consists of the Power Head together with the 3 metre Cable Assembly.
Power supply
No additional power supply is required. 12 V DC is supplied to the Power Head from the Service
Monitor, through the cable assembly.
Procedure
RF HAZARD. No attempt should be made to connect the Directional Power Head to an RF
line until the "Operating Precautions" on page v have been noted.
Connect the accessory cable between the seven pin ACCESSORY IN/OUT socket on the Service
Monitor front panel, and the seven pin DIN socket on the Power Head. These connections can be
made with the instrument powered up.
Select either the Tx or Dx operating mode by pressing the appropriate mode key.
Press the [Tx Freq] key which will display the screen shown in fold out diagram (2.1) or (4.8).
Press the [Dir Power] key. The screen shown in Fig. A-5 will be displayed.
Fig. A-5 Directional power head screen
The power head is now installed and the Service Monitor ready to make directional power
measurements.
Ensure that transmitter power is OFF and an antenna or load is connected to the transmitter.
Connect the Power Head in series with the transmitter output using either of the N sockets for input
or output.
The Directional Power Head is able to operate in two modes, CW and PEP (when using AM or
SSB). When the DIRECTIONAL POWER METER display first appears, it is in CW mode. Select
CW or PEP as appropriate, using the [CW/PEP] key.
Switch on the transmitter under test. Readings appear for forward power, reverse power and
VSWR. The values appear on three horizontal bar charts.
The forward and reverse power levels and the VSWR level, are each displayed as digital readouts
with a maximum resolution of three figures. Below 10 mW the power readings are reduced to a
single figure, with two digits resolution up to 99 mW.