LOCAL OPERATION
3-92 46882-311D
Setting up
Logic line state
The state of the logic lines outputs can be set from the logic lines setup menu, accessible by the
key sequence, [HELP/SETUP], [Setup], [Setup Page 2], [Logic Lines].
The top four soft keys on the right of the display control the normal state of the logic lines.
Pressing these keys will set the options alternately.
If the appropriate section of S1 is closed, the output can be set to either logic high or logic low. If
the appropriate section of S1 is open, the contacts between pin pairs can be set to opened or
closed. Switch S1 is mounted within the option assembly, on the printed circuit board. The
option assembly must be removed from the service monitor to have access to S1. Remove the
power connection from the service monitor, and any connections from the option assembly before
removing it from the service monitor. After making changes to S1, refit the option assembly to
the service monitor before re-connecting the power lead. Each of the four lines can be set
individually.
When any section of S1 is closed, and the connector output of that line (pins 2,3,4 or 5) is at a
logic state high, the associated pin (6,7,8 or 9) will also be at logic state high.
When any section of S1 is open, and the connector output of that line (pins 2,3,4 or 5) is at a logic
state low, the associated pin (6,7,8 or 9) will be open circuit.
Logic line control
Additional control is provided to logic lines 0 and 1, from the two top soft keys on the left of the
logic line setup menu.
When set to ‘As setting’, the output will be as set by the right-hand soft keys.
When the ‘Line 0 Mode’ is set to ‘Close for Transmit’, the state of this line will depend upon
which operating mode the instrument is set to.
When the instrument is in the Rx TEST mode, line 0 will take up the ‘Closed/Logic High’ state,
and the ‘Open/Logic Low’ state for all other test modes.
The ‘Press To Talk’ switch on the accessory microphone, if this accessory is fitted, will switch the
instrument from Rx TEST mode to Tx TEST mode. Therefore line 0 will also change state when
the ‘Press To Talk’ switch is operated.
When the ‘Line 1 Mode’ is set to ‘Close on Squelch’, line 1 will take up the ‘Closed/Logic High’
state when the instrument is in a squelched condition, and the ‘Open/Logic Low’ state when the
instrument is not squelched.