Aeroflex 2946A Manuel d'utilisateur Page 4

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 7
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 3
400 MHz
Difference of Depth of Modulation (DDM)
0-45% glideslope, 0-25% localiser in 0.1% steps
limited by SDM
Selection
Keyboard entry and variation of rotary control
Localiser Presets
0, 4.6, 9.3 and 15.5% DDM
Glideslope Presets
0, 4.5, 9.1 and 17.5% DDM
Accuracy of DDM
At 0 dBm 0.001 DDM (20% depth)
Tone Frequencies
90 Hz and 150 Hz (either tone can be suppressed)
Additional Modulation
1020 Hz ident signal available on 0 DDM on ILS
from an internal modulation source
VOR MODE
9.96 kHz Sub-Carrier Range
0-99.0% in 0.1% steps
Modulation
FM by a 30 Hz tone with 480 Hz deviation
30 Hz Tone Range
0-99% in 0.1% steps
Bearing Control
Relative phase of the 30 Hz tone and sub-carrier
modulation adjustable from 0 to 360° in 0.1° steps
by entering VOR bearing. Bearing can be entered as
TO or FROM the beacon.
Automatic VOR Test
Bearing automatically increments in 0.1° steps
Bearing Accuracy
±0.5°
Additional Modulation
Ident signal (1020 Hz). Available on 0° bearing from
an internal source
SELCAL MODE
Provides amplitude modulation with SELCAL tones
Data Entry
By table selection of 2 pairs of characters
labelled ‘A’ to ‘S’
Timing
1 s tone duration, 250 ms gap
MARKER BEACON MODE
Provides default modulation of 95% AM depth on a
75 MHz carrier at the rate of 400 Hz (outer
beacon), 1.3 kHz (middle beacon) or 3 kHz (inner
beacon). AM depth, carrier frequency and
modulation frequencies can be changed from default
values.
FREQUENCY
Frequency Range
400 kHz to 1.05 GHz
Resolution
10 Hz
Indication
10 digit display
Setting
Keyboard entry, delta increment/decrement function
and rotary control
Accuracy
As frequency standard
OUTPUT LEVEL
Output Level Range
Rx Test:
N-Type socket: -141 dBm to -21 dBm
BNC socket: -115 dBm to +5 dBm
(overrange to +7dBm)
Resolution
0.1 dB
Indication
4 digits plus sign (dBm, dBµV, µV, mV PD/EMF)
Accuracy
±2 dB for level above -127 dBm on N-Type socket
up to 1 GHz
Reverse Power Protection
N-Type: 50 W continuous, normal operation. 150 W
for 1 minute at 20 °C.
Overload indicated by audible and visual warning.
BNC: 5 W Overload indicated by audible and visual
warning.
Output Impedance
Nominally 50
VSWR
N-Type
Better than 1.2:1 up to 500 MHz
Better than 1.35:1 up to 1.05 GHz
BNC
Better than 2.2:1 up to 1.05 GHz
SPECTRAL PURITY
(If you require even better spectral purity than that
specified here, please consider the 2948)
Residual FM
Less than 15 Hz RMS (0.3 to 3.4 kHz) up to
500 MHz
Less than 20 Hz RMS (0.3 to 3.4 kHz) up to
1.0 GHz (with OCXO)
Harmonics
Better than 20 dBc
Spurious Signals
Better than 30 dBc (±10 kHz to 1.5 MHz offset
from carrier frequency or over range 600 to
700 MHz).
Better than 40 dBc from 400 kHz to 1 GHz
SSB Phase Noise (20 kHz offset)
Better than -95 dBc/Hz up to 1 GHz
RF Carrier Leakage
Less than 0.5 µV PD generated in a 50 load by a
2 turn loop 25 mm from the case. Output level less
than 40 dBm into a sealed 50 load.
AMPLITUDE MODULATION - INTERNAL
Frequency Range
400 kHz to 1.05 GHz
AM Depth Range
0 to 99%
Resolution
1%
Indication
2 digits
Setting
Keyboard entry, delta increment / decrement
function and rotary control
Accuracy
For carrier frequencies from 1.5 MHz to 400 MHz
± 7% ± 1digit for modulation frequency of 1 kHz.
± 10% ± 1 digit for modulation frequencies from
50 Hz to 5 kHz.
±15% ±1 digit for modulation frequencies from
50 Hz to 15 kHz.
Distortion
Less than 2% at 1 kHz for 30% AM, CCITT weighted
Modulation Frequency
20 Hz to 20 kHz
AMPLITUDE MODULATION - EXTERNAL
Input Impedance
Nominally 10 k in parallel with 40 pF
Frequency Range
As internal AM
Modulation Frequency Range
As internal AM
Sensitivity
1 V RMS for 100% AM
FREQUENCY MODULATION - INTERNAL
Frequency Range
400 kHz to 1.05 GHz
Maximum Deviation
75 kHz
Indication
3 digits
Setting
Keyboard entry, delta increment/decrement function
and rotary control
Accuracy
(1)
±5% ± 10 Hz at 1 kHz modulating frequency.
±10% at modulating frequencies from 50 Hz to
15 kHz.
Distortion
Less than 1% at 1 kHz for deviation of 5 kHz, CCITT
weighted
Modulation Frequency Range
20 Hz to 25 kHz
Resolution
25 Hz
Pre-emphasis
750 µs selectable
FREQUENCY MODULATION - EXTERNAL
Input Impedance
Nominally 10 k in parallel with 40 pF
Frequency Range
As internal FM
Modulation Frequency Range
DC to 100 kHz
Pre-emphasis
750 µs selectable
Sensitivity
1 Volt RMS for 0 to 75 kHz deviation
MICROPHONE INPUT
Input Level
2 mV to 200 mV (AGC levelled)
Input Impedance
Nominally 150
Press To Talk (PTT)
When using the optional microphone in Tx Test
mode, the PTT will switch instrument to Rx Test.
Input Impedance
Nominally 1 M in parallel with 40 pF
Frequency Range
DC and 20 Hz to 50 kHz
AC only 20 Hz to 50 kHz
Level Ranges
0 to 100 mV to 0 to 100 V RMS in a 1, 3, 10
sequence.
Digital readout also in mW (user selectable)
Resolution
1 mV or 1% of reading
Indication
3 digits and bar-chart
Audio Voltmeter
RF Signal Generator
3