Model 8210A-2-5 IM-377
Aeroflex / Weinschel
1
Manual Rev. 01-10
Firmware Version 1.00
Operation & Installation Manual
SmartStep
Programmable Attenuator/Switch Controller
(Model 8210A-2-5)
This documentation may not be reproduced in any form, for any
purpose unless authorized in writing by Aeroflex / Weinschel, Inc.
© Aeroflex / Weinschel, Inc.
Frederick, Maryland
2003 - 2010
IM-377
Vue de la page 0
1 2 3 4 5 6 ... 55 56

Résumé du contenu

Page 1 - (Model 8210A-2-5)

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 1Manual Rev. 01-10 Firmware Version 1.00 Operation & Installation Manual SmartStep Prog

Page 2 - TABLE OF CONTENTS

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 10 5. SERIAL (RS-232, RS-232 & RS-485) OPERATION: 5-1. SERIAL COMMUNICATIONS SETTINGS: The Serial C

Page 3

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 11 Figure 4. Model 8210A-2-5 Internal Switch Locations 6-2. Serial Operation. The serial interface

Page 4 - 1. GENERAL INFORMATION:

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 12 Software handshaking uses the XON/XOFF scheme in which an ASCII DC3 (0x13) character is transmitte

Page 5

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 13 5-3. RS-232 Operation: The RS-232 Serial port is a 9-pin connector that is compatible with the pi

Page 6 - CAUTION

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 14 5-4. RS-422/RS485 OPERATION: The RS422/RS485 Serial mode is useful in applications requiring long

Page 7 - 2. SPECIFICATIONS:

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 15 6. DEVICE INTERFACE BUS (DIB) OPERATION 6-1. GENERAL OPERATION: The Device Interface Bus is a seri

Page 8 - 3. PHYSICAL DIMENSIONS:

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 16 6-2. DIB CONNECTOR. This connector (shown below) is a 14-pin 0.025" square post header @ 0.1&q

Page 9 - 4. INSTALLATION:

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 17 7. CONFIGURING & USING THE 8210A-2-5 7-1. MANUFACTURING SELECT SWITCH SW3: NOTE: DO NOT change t

Page 10

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 18 Currently, there are four protocols. These are the Base, Attn, StepAttn, and Switch protocols. They

Page 11

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 19 The 8210A-2-5 currently supports up to 4 attenuator groups, each of which allow up to 32 physical or

Page 12

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 2 TABLE OF CONTENTS 1. GENERAL INFORMATION ...

Page 13

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 20 Standard Event Status Register/ Standard Event Status Enable Register Formats D7 D6 D5 D4 D3 D2 D

Page 14

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 21 7-8.2 SYNTAX OF COMMANDS: A command message unit is made up of a command header, optionally followed

Page 15

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 22 7-8.3 OUTPUT DATA FORMAT. Output data from the Model 8210A-2-5 consists of a series of ASCII digits

Page 16

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 23 7-9. 488.2 COMMON COMMANDS *CLS Function: Clears the Status Byte and Event Status Registers.

Page 17

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 24 *RST Function: Performs a device reset. Syntax: *RST Argument(s): none Remarks: This funct

Page 18

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 25 7-10. Device Assignment & Configuration Commands ASSIGN? Function: Assign a name to a physical

Page 19 - RQS ESB MAV

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 26 REASSIGN Function: Reassign device names. Syntax: REASSIGN Argument(s): none Remarks: This

Page 20

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 27 ADDR? Function: Reads the Device Interface Bus address assigned to a device. Syntax: This com

Page 21

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 28 7-11. Attenuator Assignment ASSIGN ATTN Function: Assign a virtual attenuator Syntax: ASSIGN AT

Page 22

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 29 7-12. Attenuator Control ATTN Function: Set attenuation Syntax: ATTN name atten (specific form

Page 23

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 3 7-8. GENERAL SYNTAX STRUCTURE ...

Page 24 - Aeroflex / Weinschel

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 30 RELATTN? Function: Read relative attenuation Syntax: RELATTN? name Argument(s): name str

Page 25

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 31 ATTN? GETCAP Function: Reads the capability of an attenuator Syntax: ATTN? GETCAP name Argu

Page 26

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 32 7-13. Switch Assignment ASSIGN SWITCH Function: Assign a virtual switch Syntax: ASSIGN SWITC

Page 27

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 33 7-14. Switch Control SWITCH Function: Set switch value Syntax: SWITCH name setting (specific

Page 28

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 34 7-15. Group Assignment GROUP Function: Assign a group of attenuators Syntax: GROUP groupname

Page 29 - 7-12. Attenuator Control

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 35 7-16. Macro Commands MACRO Function: Define a macro Syntax: MACRO name text Argument(s): na

Page 30

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 36 7-17. Memory Commands DELETE Function: Deletes an assigned device name, virtual attenuator, virtual

Page 31

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 37 7-18. MISC Commands REBOOT Function: Performs a complete system reset Syntax: REBOOT Argumen

Page 32

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 38 IDN Function: Assigns system model, and serial number Syntax: IDN model serialno Argument(s):

Page 33

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 39 7-20. Base Protocol Commands DEVICE RESET Function: Sends a Reset msg to the device Syntax: DEVIC

Page 34

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 4 1. GENERAL INFORMATION: 1-1 PURPOSE: This manual contains setup and operation information for the Ae

Page 35

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 40 7-21. Step Attenuator Protocol Commands DEVICE ATTN Function: Sets the attenuation of a device

Page 36

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 41 DEVICE? READ COUNTER Function: Reads the cycle counter for the specified relay cell Syntax:

Page 37

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 42 7-22. Switch Protocol Commands DEVICE SET Function: Sets the output of a device Syntax: DEVICE

Page 38

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 43 9. Programming and Configuration Examples Example 1: Single Attenuator If there is only one atte

Page 39 - 7-20. Base Protocol Commands

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 44 Example 3: Virtual Attenuator In this example, we will use two attenuators to create a virtual att

Page 40

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 45 Example 4: Attenuator Groups In this example, we will use four attenuators to create an attenuator

Page 41

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 46 Example 5: Multiple Virtual Attenuators with Groups In this example, we will use eight attenuators

Page 42

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 47 Example 6: Single SPDT Switch This example shows using the Relay Output Card (Model 193-8015) to co

Page 43

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 48 Example 8: Multiple SP4T Switches (Virtual Switch) This example shows using the Relay Output Card (

Page 44

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 49 Example 9: Using macros to simplify programming multiple RF Switches This example shows how using m

Page 45

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 5 1-4. UNPACKING AND INSPECTION: Upon unpacking the equipment, retain the shipping container and packin

Page 46

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 50 10. Maintenance: The Model 8210A-2-5 SmartStep Interface requires no scheduled or preventive mainten

Page 47

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 51 13. Contacting Aeroflex / Weinschel: In the event of a malfunction, contact Aeroflex / Weinschel. A

Page 49

Aeroflex / Weinschel Revised 8-30-03 APPENDIX A - Reserved Keywords *CLS *ESE *ESE? *ESR? *IDN? *OPC *OPC? *RST *SRE *SRE? *STB? *TST? *WAI ADDR AP

Page 50 - 12. Accessories:

Aeroflex / Weinschel Revised 8-30-03 APPENDIX B – 488.2 Documentation Number Required Item Implementation 1 Interface Function Subsets Implemented

Page 51

Model 8210A-2-5 (IM-355) Revision Record REVISION DATE DESCRIPTION APPLICABLE SERIAL NUMBERS A 9/03 Initial Issue All Units B 4/04 Company N

Page 52

EC DECLARATION OF CONFORMITY This is to certify that the: SmartStep Programmable Attenuator & Controller 3200T-2 & 8210A-1/2 Manufacture

Page 53 - Reserved Keywords

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 6 1-7. RELATED MANUALS: The following manuals contain information that may be used in conjunction with

Page 54 - 488.2 Documentation

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 7 2. SPECIFICATIONS: DC Input Connector: 2.5mm barrel style Requirements: +5 Vdc @ 375 mA Driver I

Page 55

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 8 3. PHYSICAL DIMENSIONS: Note: All dimensions are given in mm (inches) and are maximum, unless

Page 56 - 3200T-2 & 8210A-1/2

Model 8210A-2-5 IM-377 Aeroflex / Weinschel 9 4. INSTALLATION: 4-1. MOUNTING: Each SmartStep Interface is supplied with four 4-40 UNC-2B mounting